products

Portable Sulfonamide (SulQ) Antibiotic Milk Test Kits 96 T / Kit Easy To Use

Basic Information
Place of Origin: CHINA
Brand Name: MTUSBIO
Certification: ISO9001 FDA ROSH
Model Number: MT2015019
Minimum Order Quantity: 10BOXES
Price: USD 120-150 Pre box
Packaging Details: customer request
Delivery Time: 10days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 10000boxes pre month
Contact Now
Detail Information
Specification: 96T/kit Expiry Date: 12 Months
High Light:

milk testing strips

,

antibiotic residue test kit


Product Description

Sulfonamide (SulQ) Rapid Test Strip
 
【Product Name】
Sulfonamide (SulQ) Rapid Test Strip
【Specification】 96T/kit
【Storage Conditions】
 Store at 2-8℃ in dry environment.
 Expiry date: 12 months
【Intended Application】
The test strip is used for detecting Sulfonamide family in raw
commingled cow milk above or below tolerance and/or safe levels.
【Principle】
The kit is a competitive colloidal gold immunoassay method. Sample
is added to sample hole, if there is Sulfonamide (SulQ) in samples, it
will combine with marked antibodies, preventing the marked
antibodies from combining the Sulfonamide (SulQ) antigens of NC
nitrocellulose membrane.
【Technique Data】
 Kit sensitivity: 5/100 ppb (ng/ml) (Final detection limit)
【Kit Contents
Test strip ………………………… 12*8T/kit
96 well tray and sample well with reagent.
Instruction …………………………..1
【Milk Sample Preparation】
1. Collect milk sample from butch, or farm
2. Make sure the milk has no clot.
3. Milk at room temperature, don’t heat or freeze.
4. Thoroughly mix with the reagent before testing.
【Test Procedure】
1. Read the manual instruction before testing. Be sure the raw
commingled milk and test kit is at room temperature.
2. Take one Tube from the box, open tube and take out decided
number of test to be perform, Use the test kit within an hour
beyond time may cause failure of the test. The unused test strip
must be sealed and keep out from sunlight and prevent
moisture.
3. Take the milk sample, drop 200ul (about 4-5drops) into the
sample-well, and thoroughly dissolve the milk with reagents for
5 minutes till the milk presents pink color.
4. Insert the test strip into the sample-well, read the results
after 5 minutes.
【Results Judgment】
Negative(-): control line(C) display red, test line(T) color is
deeper than the control line or the same as the C line, the
result shows that (SulQ) concentration is less than detection
Limits or not containing (SulQ).
Positive(+): control line(C) display red, test line(T) color is
shallower than the control line or no color, the result shows
that (SulQ) concentration is higher than detection Limits.
Invalid: control line (C) doesn’t display, it means the
operational process is incorrect or this test card
has lost efficacy.
【Notice】
 Don’t use the expired or damaged
products
 The test card removed from refrigerator
should place at room temperature and
should be used as soon as possible to
avoid failure when wet
 Don’t touch sample hole and white
nitrocellulose (NC) membrane
 Don’t mix micropipette to avoid cross
contamination
 Samples should be clear, not turbid
particles and not clogged; if not, it will
easily lead to blocking and
inconspicuous color, which will affect
the judgment of the experimental
results

Contact Details