Place of Origin: | GUANGZHOU |
---|---|
Brand Name: | MTUSBIO |
Certification: | CE,ISO9001 |
Model Number: | M231181 |
Minimum Order Quantity: | 1BOX/40T |
Price: | USD 4.8/T-199/BOX |
Packaging Details: | 15*13*11CM, carton |
Delivery Time: | 15 WORK DAYS |
Payment Terms: | T/T, Western Union |
Supply Ability: | 50000 BOX /PER 30 DAY |
Aflatoxin Colloidal Gold Rapid Detection Card
operation instructions
(Colloidal gold method)
1. Principle and Application
This product is made by the principle of competitive inhibition colloidal gold immunochromatography, and is used to detect the total amount of Aspergillus flavus (AFT) in grains, feedstuffs and other samples.
After the sample solution is dropped into the sample adding hole of the detection card, the Aspergillus flavus in the sample solution combines with the gold labeled antibody, thus preventing the gold labeled antibody from combining with the Aspergillus flavus conjugate on the cellulose membrane. When the content of Aspergillus flavus in the sample solution is greater than the detection limit, the detection line does not show color, and the result is positive; When the content of Aspergillus flavus in the sample solution is less than the detection limit, the detection line shows purple red, and the result is negative.
2. Technical indicators
2.1 Sensitivity of reagent card: 1ppb (ng/ml)
The final detection limit for the sample must be determined by multiplying the sensitivity of the reagent card by the dilution ratio of the sample treatment.
2.2 Lower limit of sample detection:
Cereals, feed, grain and oil...... 5ppb
3. Kit composition
Detection card: 50 pieces/box
Instructions: 1 copy
4. Required equipment and reagents
4.1 Instruments: homogenizer, oscillator, centrifuge, graduated pipette, balance (sensitivity 0.01g)
4.2 Micro Pipette: single channel 20 µ l-200 µ l, 100 µ l-1000 µ l
4.3 Reagent: Methanol, n-hexane
5. Sample pretreatment
5.1 Instructions before sample processing:
The experimental equipment must be clean and use a disposable suction head to avoid contamination and interference with the experimental results.
5.2 Preparation:
Solution 1: Sample extraction solution
70% methanol, i.e. V methanol: V deionized water=7:3.
5.3 Sample preprocessing steps:
5.3.1 Cereals and feed
1) Weigh 1g of crushed sample into a centrifuge tube, and add sample extraction solution according to different detection limit requirements in the following table
Limit of detection | 5ppb | 10ppb | 20ppb | 50ppb |
Sample extraction solution | 2ml | 4ml | 8ml | 20ml |
Shake for 5 minutes at room temperature of 4000 rpm/separation heart for 5 minutes.
2)Take 0.1ml of supernatant, add 0.15ml of deionized water, mix well and set aside.
5.3.2 Grain and oil (vegetable oil, sesame oil, salad oil, Peanut oil, etc.)
1) Weigh 1g of sample into a centrifuge tube, and add sample extraction solution according to different detection limit requirements as shown in the table below
limit of detection | 5ppb | 10ppb | 20ppb | 50ppb |
Sample extraction solution | 2ml | 4ml | 8ml | 20ml |
Then add 8ml of n-hexane, shake for 5 minutes, and separate at room temperature of 4000 rpm for 10 minutes.
2) Remove the upper liquid, take 0.1ml of the lower liquid and add 0.15ml of deionized water, mix well and set aside.
6. Experimental Steps
6.1 Tear open the aluminum foil packaging bag of the inspection card, take out the inspection card, and place it on a flat and clean tabletop.
6.2 Suck the prepared sample liquid with a matching pipette, and slowly drop 2-3 drops (about 60ul) into the sample hole (S) one by one (foam should be avoided).
6.3 Leave at room temperature for 8-10 minutes to determine the results. Results exceeding 10 minutes can only be used as a reference.
7. Result judgment
Negative positive invalid invalid
Negative: Both the C and T lines show color, indicating that the concentration in the sample is below the detection limit or does not contain.
Positive: The C line shows red, while the T line does not show color, indicating that the concentration in the sample is above the detection limit.
Invalid: The absence of a quality control C-line indicates an incorrect operating process or a failure of the detection card.
8. Precautions
8.1 Products that have expired or have damaged aluminum foil bags cannot be used.
8.2 When removing the detection card from the refrigerator, it should be restored to room temperature before opening. The opened detection card should be used as soon as possible to avoid failure due to moisture.
8.3 Do not touch the white film surface in the center of the detection card.
8.4 Droppers should not be mixed to avoid cross contamination.
8.5 The sample solution to be tested should be clear, free from turbid particles, and bacterial contamination, otherwise it may lead to abnormal phenomena such as blockage and unclear color development, which may affect the judgment of experimental results.
9. Storage and shelf life
Storage conditions: The reagent kit should be stored in a dry environment at 2-30 ℃.
Shelf life: The product has a validity period of 1 year, and the production date can be found in the packaging box.